Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 70/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Shenzhen K-Easy Automation Co.,Limited is a professional manufacturer, specialize in R&D And production of AC drives. We have built up a comprehensive product family. Frequency inverters' power covers the range from 0.4 to 630kW, and voltage range is between 220V and 480V. More than inverters are running smoothly 300, 000 units at different industrial sites.
Performance | K-Drive |
---|---|
Applicable motors | Asynchronous /synchronous motors |
Starting torque | 0.5Hz, 180% (sensor-less vector control) 0Hz, 200% (closed-loop vector control) |
Speed adjustable range | 1:200 (SVC), 1:1000 (VC) |
Ambient temperature (no derating required) | -10-50ºC (for most of the models) |
Rated input voltage | 208VAC-480VAC |
Communication | Modbus RTU//ASCII Profibus-DP, CANopen, etc. |
Position control (fixed length, or angular positioning) | √ |
Field weakening control | √ |
Autotune online | Online & Offline |
Short-time ramp-up | No trip |
Customized features (software and/or hardware) | Procurable with rich experience |
lt is compatible with pulse signal input and /0internal control mode. One driveis with multiple functions bringing more expansionpossibilities, greatly reducing system costs.
With RS485 communication connection, based on standard ModbusRTU protocolit can support mult-axis RS485 motion control network
There is an inherent resonance point in the stepping system. The C series of stepper drives adopts an excellent anti-resonance algorithmto capture the characterstics of the resonance point which can effectively avoid or suppress the resonance point and improve the stabilitat medium andlow speeds and torque output at high speed.
The built-in T-type and S-type command smoothing technology reduces the instantaneous disturbance caused by the load movement anotransmission machinery so that it can make the motor movement more stable and smoothy
During the set acceleration time, the speed accelerates fr-om theinitial value to the set maximum value, and continues to run at themaximum speed.
It can be configured with 2-segment position table program supporting positioning/emergencystop/zero return and other functions, whichcan save the number of pulse output points of the host controller.